toyota soarer 1994
Primary Voltage Patterns::
The primary pattern shows us how long it is grounded for, how much voltage is used to cross the gap (burn voltage) and how long it takes to cross (burn time) This is good to help with diagnosis because it shows how strong the burn voltage is and the time it takes to cross. (a good way is string theory) higher burn voltage short burn time, low burn voltage long burn time.
Secondary Voltage Patterns::
The graph shows us a similar pattern as the primary jus the firing voltage isnt as high but the burn time is the same. In the secondary pattern it shows At snap acceleration you notice straight away the burn voltage goes down and it has a longer burn time. This is as expected
NOTE: The primary curcuit colapses on it self inducing a voltage in the secondary of similar voltage. same pattern.